PRODUCTEN
EShop-nummer
Wachtwoord
Welcome to CAIROX BELGIUM

WSYG/WSYK SHP • A2W Super High Power heat pumps <60°C

Air/water DC inverter controlled heat pump. The outside air is the energy source for this heat pump. This energy is transferred by the heat pump to the water in the heating circuit(s). Thanks to the "Liquid injection technology" it is possible to reach a water temperature of 60°C even at an outside temperature of -20°C. The fan and compressor speeds are modulated according to the heat requirements.

Brand

  • Fujitsu - Airstage

Application

  • Heating for residential and commercial applications
  • Heating by means of radiators, convectors, floor, wall and ceiling heating
  • Production of domestic hot water
  • Ideal for the renovation market

Composition

  • High-quality coaxial heat exchanger that ensures efficient defrosting (even at extreme outdoor temperatures)
  • Buffer tank (25 litres)
  • User-friendly Siemens controller
  • Energy-efficient circulation pump
  • Expansion vessel (10 litres)
  • Safety valve (3 bar)
  • Electrical back-up resistance hydro unit (2 x 3 kW for WSYG /3 x 3 kW for WSYK)
  • Outside temperature sensor
  • Water pressure gauge

Refrigerant

  • R410A

Specifications

  • Split system
  • Single-phase and three-phase
  • 1 device for 2 applications: heating and domestic hot water
    • Heating assured to -20°C outside temperature
    • Water temperature up to 60°C at -20°C outside temperature (without using a electrical resistance)
  • Liquid Injection Technology: thanks to this technology, it is possible to maintain power and increase efficiency to an unprecedented height of A++
  • Intelligent heating curve (adjustment)
  • Control of 2 heating circuits
  • Can be connected to the PC via an optional web server for remote control of the heat pump
  • Approved according to EN 14511-2 and EN 14511-3
  • Integrated user-friendly controller, also available in Dutch and French aong others

Accessories

  • Room thermostat, type UTW-C55XA
  • Room thermostat RF, type UTW-C58XD + UTW-MRCXD
  • Remote control with room temperature sensor, type UTW-C74TXF
  • Remote control with room temperature and humidity sensor, type UTW-C74HXF
  • Kit for 2nd external circuit WSYA/WSYG/WSYK, type UTW-KZSXJ
  • External boiler connection kit WSYA/WSYG/WSYK, type UTW-KBSXJ + UTW-KREXD
  • Low Noise kit, type UTW-KLNXE
  • Integrated web server, type UTW-KW1XD
  • External heater kit, type UTW-KDWXD
  • Outdoor sensor RF, type UTW-MOSXD + UTW-MRCXD
  • RF module, type UTW-MRCXD
  • Insulation kit for cooling, type UTW-KCLXD
  • Hydraulic decoupling bottle, type UTW-TEVXA
  • External control kit, type UTW-KREXD
  • External control kit, type UTY-XWZXZ2
  • Pump high head, type PHFXG

Applicable outdoor units

Waterstage Comfort Fujitsu outdoor unit
  • Type WOYG 160 LJL (single-phase)
  • Type WOYK 150 LJL (three-phase)
  • Type WOYK 170 LJL (three-phase)

Applicable boiler

  • Warm water heater 300 liter, type SANI+ 300
  • Warm water heater 500 liter, type SANI+ 500

Articles

Article selection assistant
Battery type
Configuration
Type
Size
Article number Battery type Configuration Type Size E-shop Spare parts
I100880000601 BC DIVA SILVERTOP 06 PRE BC DIVA 6
I100880000602 BC LOBBY SILVERTOP 06 PRE BC LOBBY 6
I100880000801 BC DIVA SILVERTOP 08 PRE BC DIVA 8
I100880000802 BC LOBBY SILVERTOP 08 PRE BC LOBBY 8
I100880001501 BC DIVA SILVERTOP 15 PRE BC DIVA 15
I100880001502 BC LOBBY SILVERTOP 15 PRE BC LOBBY 15
I100880001503 BC MAC2 SILVERTOP 15 PRE BC MAC2 15
I100880001504 BC QUATTR SILVERTOP 15 PRE BC QUATTR 15
I100880002301 BC DIVA SILVERTOP 23 PRE BC DIVA 23
I100880002302 BC LOBBY SILVERTOP 23 PRE BC LOBBY 23
I100880002303 BC MAC2 SILVERTOP 23 PRE BC MAC2 23
I100880002304 BC QUATTR SILVERTOP 23 PRE BC QUATTR 23
I100880003501 BC DIVA SILVERTOP 35 PRE BC DIVA 35
I100880003502 BC LOBBY SILVERTOP 35 PRE BC LOBBY 35
I100880003503 BC MAC2 SILVERTOP 35 PRE BC MAC2 35
I100880003504 BC QUATTR SILVERTOP 35 PRE BC QUATTR 35
I100880005201 BC DIVA SILVERTOP 52 PRE BC DIVA 52
I100880005202 BC LOBBY SILVERTOP 52 PRE BC LOBBY 52
I100880005203 BC MAC2 SILVERTOP 52 PRE BC MAC2 52
I100880005204 BC QUATTR SILVERTOP 52 PRE BC QUATTR 52
I100881000601 BE DIVA SILVERTOP 06 PRE BE DIVA 6
I100881000602 BE LOBBY SILVERTOP 06 PRE BE LOBBY 6
I100881000801 BE DIVA SILVERTOP 08 PRE BE DIVA 8
I100881000802 BE LOBBY SILVERTOP 08 PRE BE LOBBY 8
I100881001501 BE DIVA SILVERTOP 15 PRE BE DIVA 15
I100881001502 BE LOBBY SILVERTOP 15 PRE BE LOBBY 15
I100881001503 BE MAC2 SILVERTOP 15 PRE BE MAC2 15
I100881001504 BE QUATTR SILVERTOP 15 PRE BE QUATTR 15
I100881002301 BE DIVA SILVERTOP 23 PRE BE DIVA 23
I100881002302 BE LOBBY SILVERTOP 23 PRE BE LOBBY 23
I100881002303 BE MAC2 SILVERTOP 23 PRE BE MAC2 23
I100881002304 BE QUATTR SILVERTOP 23 PRE BE QUATTR 23
I100881003501 BE DIVA SILVERTOP 35 PRE BE DIVA 35
I100881003502 BE LOBBY SILVERTOP 35 PRE BE LOBBY 35
I100881003503 BE MAC2 SILVERTOP 35 PRE BE MAC2 35
I100881003504 BE QUATTR SILVERTOP 35 PRE BE QUATTR 35
I100881005201 BE DIVA SILVERTOP 52 PRE BE DIVA 52
I100881005202 BE LOBBY SILVERTOP 52 PRE BE LOBBY 52
I100881005203 BE MAC2 SILVERTOP 52 PRE BE MAC2 52
I100881005204 BE QUATTR SILVERTOP 52 PRE BE QUATTR 52

Startup

  • Start-up by CAIROX BELGIUM is strongly recommended

Technical data

Indoor unit* WSYG 160 DJ6WSYK 170 DJ9WSYK 170 DJ9
Associated outdoor unit* WOYG 160 LJLWOYK 150 LJLWOYK 170 LJL
CapacityHeating (-10°C/+35°C)*kW14.814.0515.04
Heating (-10°C/+55°C)*kW11.4312.5513.44
HeatingNom. capacity (+7°C/+35°C)*kW161517
Min - Max capacity (+7°C/+35°C)kW(6,59-22,93)(6,63-22,7)(6,78-24,27)
Absorbed electric powerkW3.863.464.1
COP 4.144.334.15
Nom. capacity (+2°C/+35°C)*kW13.313.213.5
Absorbed electric powerkW4.254.064.27
COP 3.133.253.16
Nom. capacity (+7°C/+55°C)*kW14.513.215
Absorbed electric powerkW5.584.775.49
COP 2.62.772.73
Liquid injection (compressor) Yes
Backup heating resistance Yes (2 x 3kW)Yes (3 x 3kW)
Cooling  Optional
Seasonal efficiency ηs heat pump35°C/55°C163/125164/130161/130
Annual consumption heat pumpkWh 35°C/55°C8014/87578606/99159059/10232
Ecolabel heat pump35°C/55°CA++/A++A++/A++A++/A++
Refrigerant (GWP) R410A (2088)R410A (2088)R410A (2088)
Indoor unitMaximum water flow ratel/min57.854.261.4
Minimum water flow ratel/min26.42427.3
Max. operational working pressure (heating)Bar3
Max. operational working pressure (DHW tank)Bar5.5
Min/Max. water output°C+8 / +60°C
Water volumeL25
Expansion vessel***L10
Sound level @ 1mdB46
Dimensions (H x W x D)mm805x450x471
Weightkg52.5
Colour White (RAL 9003)
Hydraulic connection diameterinch2 x 1"
Main pipe diameterinch1"
Condensate drain pipe diametermm32
Relative humidity limit%15~95
Type of heat exchanger Coaxial heat exchanger
Electrical - Hydraulic modulePower supply hydraulic moduleV230V/1Ph400V/3Ph+N400V/3Ph+N
Max. absorbed power (backup resistance)A281414
Automatic fuse (slow)A322020
Power supply cable section of backup resistancemm²3G65G2,55G2,5
Section between indoor unit and outdoor unitmm²4G1,54G1,54G1,5
TechnicalRefrigerant pipes indoor/outdoorinch3/8 - 5/83/8 - 5/83/8 - 5/8
Standard prefilled refrigerantg (CO2eq-T)2500 (5,2)2500 (5,2)2500 (5,2)
Prefilled piping lengthm151515
Additionnal refrigerant R410Ag/m505050
Min./max. piping lengthm5/305/305/30
Max. height difference (Outdoor unit above/under)m25/1525/1525/15
Expansion Outdoor unitOutdoor unitOutdoor unit
* Specifications and design can be modified for further improvement without prior notice
** Capacities measured according to EN14511 measuring method
*** The size of the expansion vessel has to be determined in accordance with the total water volume of the system

HELPCopyrightSales conditionsCookie policyfujitsu-airco.be

Informatie aanvragen. Even geduld a.u.b...